โปรดเลือกที่อยู่การจัดส่ง

การเลือก ประเทศ/ภูมิภาค อาจส่งผลต่อปัจจัยต่างๆ เช่น ราคา ตัวเลือกการจัดส่งและความพร้อมจำหน่ายสินค้า
ผู้ติดต่อของฉัน
IGUS MOTION PLASTICS (THAILAND) CO., LTD.

1340 Soi Bangkok-Nonthaburi 30, Bangkok-Nonthaburi Rd.,

Bangsue, Bangsue

Bangkok 10800 Thailand

+66 (0)2 587 4899
+66 (0)2 587 4898
TH(TH)

iglidur® J260 - material data

Materials table

General featuresUnitiglidur® J260test method
Densityg/cm³1,35 
Colour yellow 
Max. humidity absorption at 23°C/50% R. H.% weight0,2DIN 53495
Max. water absorption% weight0,4 
Coefficient of surface friction, dynamic, against steelµ0,06 - 0,20 
PV values max. (dry)MPa x m/s0,35 

Mechanical properties
Bending E-moduleMPa2.200DIN 53457
Tensile strength at +20 °CMPa60DIN 53452
compressive strengthMPa50 
Maximum recommended surface pressure (20° C)MPa40 
Shore D hardness 77DIN 53505

Physical and thermal properties
Max. long term application temperature°C+120 
Max. short term application temperature°C+140 
Lower application temperature°C-100 
Heat conductivity[W/m x K]0,24ASTM C 177
Coefficient of thermal expansion (at 23° C)[K-1 x 10-5]13DIN 53752

Electrical properties
Specific forward resistanceΩcm> 1012DIN IEC 93
Surface resistanceΩ> 1010DIN 53482
'Table 01: Material Data

Figure 01: Permitted pv-values for iglidur® J260 bearings


Figure 01: Permitted PV values for iglidur® J260 bearings with 1 mm wall thickness in dry operation against a steel shaft, at 20°C, installed in a steel housing.

X = Surface speed [m/s]
Y = Load [MPa]
Similar to the classic, iglidur® J, iglidur® J260 is an endurance runner with outstanding wear behavior, but provides increased margins at its long-term application temperature of +120°C.

Maximum recommended surface pressure dependent on the temperature Figure 02: Maximum recommended surface pressure dependent on the temperature (40 MPa to +20 °C)

X = Temperature [°C]
Y = Load [MPa]
Deformation under load and temperatures Figure 03: Deformation under load and temperatures

X = Load [MPa]
Y = Deformation [m/s]

Mechanical properties

Maximum recommended surface pressure represents a mechanical material parameter. Tribological conclusions cannot be drawn from it. With increasing temperatures, the compressive strength of iglidur® J260 plain bearings decreases. Fig. 02 clarifies this connection.
Figure 03 shows the elastic deformation of iglidur® J260 with radial loads. Under the maximum recommended surface pressure of 40 MPa, the deformation amounts to less than 2,5%. A potential plastic deformation depends, among other things, on the length of exposure.

m/s Rotary oscillating Linear
Constant 1 0,7 3
Short-term 2 1,4 4
Table 02: Maximum surface speeds

Permitted surface speeds

iglidur® J260 is developed for low to medium surface speeds. The maximum values stated in the Table 02 can be attained only with minor pressure loads. At the specified speeds, an increase in temperature up to the long-term permitted value can occur due to friction. In practice these limit values are not always reached.

iglidur® J260 Operating temperature
Lower - 100 °C
Upper, long-term + 120 °C
Upper, short-term + 140 °C
Secure axially in addition + 80 °C
Table 03: Temperature limits for iglidur® J260

Temperatures

The temperatures prevailing in the bearing system also have an influence on the bearing wear. The wear increases with rising temperatures, and the influence is especially marked from 80°C temperature onwards. An additional securing is recommended at temperatures higher than +80°C.

Figure 04: Coefficients of friction dependent on the surface speed, p = 0,75 MPa

X = Surface speed [m/s]
Y = Coefficient of friction μ
Figure 05: Coefficients of friction dependent on the load, v = 0,01 m/s

X = Load [MPa]
Y = Coefficient of friction μ

Friction and wear

Just like the wear resistance, the coefficient of friction µ, friction coefficient in short, also alters with the load. Interestingly the coefficient of friction decreases with increasing load, whereas an increasing surface speed causes a slight rise in the coefficient of friction (Fig. 04 and 05).

Fig. 06: Wear, rotating application with various shaft materials Figure 06: Wear, rotating application with different shaft materials, p = 1 MPa, v = 0,3 m/s
 
X = shaft materials
Y = wear [μm/km]
 
A = Aluminum, hard-anodized
B = machining steel
C = Cf53
D = Cf53, hard chrome-plated
E = St37
F = V2A
G = X90

shaft materials

Friction and wear also depend to a high degree on the shaft material. Very smooth shafts increase the coefficient of both friction and wear. A smoothed surface with an average surface finish Ra = 0.8 µm is best suited for iglidur® J260. Fig. 06 shows the results of tests of different shaft materials with plain bearings made of iglidur® J260. In this connection it is important to note that with increasing loads, the recommended hardness of the shaft increases. The "soft" shafts tend rather to wear themselves and thus increase the wear of the entire system, if the loads exceed 2 MPa. The comparison of rotation and swivelling in Figure 07 makes it very clear that iglidur J260 bearings display their strengths especially in the rotating operation.
iglidur® J260 Dry Grease Oil Water
Coefficients of friction μ 0,06–0,20 0,09 0,04 0,04
Table 04: Coefficients of friction for iglidur® J260 against steel (Ra = 1 μm, 50 HRC)
Fig. 07: Wear in swivelling and rotating Figure 07: Wear in pivoting and rotating applications with Cf53 dependent on the load
 
X = Load [MPa]
Y = Wear [μm/km]
 
A=Rotating
B=Pivoting

Medium Resistance at 20°C
Alcohols + to 0
Hydrocarbons +
Fats, oils, without additives 0 to –
Fuels
Diluted acids
Strong acids
Diluted bases + to 0
Strong bases + to 0
All specifications at room temperature [20°C] Table 05: Chemical resistance of iglidur® J260
Specific forward resistance > 1012 Ωcm
Surface resistance > 1010 Ω

chemical resistance

iglidur® J260 plain bearings are resistant to diluted alkalis, hydrocarbons and alcohols. The extremely low humidity absorption also allows them to be used in wet or humid environment.

Radioactive rays

Resistant up to a radiation intensity of 3x 102 Gy

UV-resistant

Partly resistant against UV rays

Vacuum

In application in vacuum, the potentially existent moisture content is degassed. For this reason only the dry iglidur® J260 bearings are suitable for vacuum.

Electrical properties

iglidur® J260 bearings are electrically insulating.

humidity absorption / moisture absorption

The humidity absorption of iglidur® J260 bearings amounts to about 0.2 % in standard climatic conditions. The saturation limit in water is 0.4 %. These values are so low that a consideration of the expansion due to moisture absorption can be neglected.
Effect of moisture absorption on plain bearings Diagram 10: Effect of moisture absorption
 
X = Moisture absorption [weight %]
Y = Reduction of inside diameter [%]
Maximum moisture absorption
by +23 °C/50 % r. F. 0,2 Wt.-%
Max. water absorption 0,4 Wt.-%

Table 06: Moisture absorption

Diameter
d1 [mm]
Shaft
h9 [mm]
iglidur® J260
E10 [mm]
Housing H7
[mm]
Up to 3 0 - 0,025 +0,014 +0,054 0 +0,010
> 3 to 6 0 - 0,030 +0,020 +0,068 0 +0,012
> 6 to 10 0 - 0,036 +0,025 +0,083 0 +0,015
> 10 to 18 0 - 0,043 +0,032 +0,102 0 +0,018
> 18 to 30 0 - 0,052 +0,040 +0,124 0 +0,021
> 30 to 50 0 - 0,062 +0,050 +0,150 0 +0,025
> 50 to 80 0 - 0,074 +0,060 +0,180 0 +0,030
> 80 to 120 0 - 0,087 +0,072 +0,212 0 +0,035
> 120 to 180 0 - 0,100 +0,085 +0,245 0 +0,040

Table 07: Important tolerances iaw. ISO 3547-1 after press-fitting.

Installation tolerances

iglidur® J260 bearings are standard bearings for shafts with h-tolerance (recommended minimum h9). The bearings are designed for press-fit in a housing with h7 tolerance. After the installation in a housing with nominal diameter, the inner diameter of the bearing automatically adjusts to the E10 tolerance. In certain dimensions the tolerance in dependence on the wall thickness deviates from this (See delivery program )

ที่ปรึกษาและการสนับสนุน

เรายินดีให้คำปรึกษากับคุณ

Photo
Aw Kai Hua

Product Manager iglidur® bearings ASEAN

เขียนอีเมล

จัดส่งและให้คำปรึกษา

ในบุคคล:

วันจันทร์ถึงวันศุกร์ตั้งแต่เวลา 8.30 น. - 5.30 น.

Online:

วันจันทร์ถึงวันศุกร์ตั้งแต่เวลา 8.30 น. - 5.30 น.


เงื่อนไข "Apiro", "AutoChain", "CFRIP", "chainflex", "chainge", "รางสำหรับเครน", "ConProtect", "cradle-chain", " ;CTD", "drygear", "drylin", "dryspin", "dry-tech", "dryway", "รางแบบง่าย", "e-chain®", " ระบบ e-chain® ", "e-ketten", "e-kettensysteme", "e-loop", "energy chain", " ระบบ energy chain ", "Enjoyneering", "e-skin", "e-spool", "fixflex", "flizz", "i.Cee", "ibow", "igear" , "iglidur", "igubal", "igumid", "igus", "igus พัฒนาการเคลื่อนที่", "igus:bike", "igusGO", "igutex", "iguverse" , "iguversum", "kineKIT", "kopla", "manus", "motion plastics", "motion polymers", "motionary", "พลาสติกเพื่ออายุการใช้งานที่ยาวนานขึ้น", "print2mold" , "Rawbot", "RBTX", "readycable", "readychain", "ReBeL", "ReCyycle", "reguse", "robolink", "Rohbot", "savfe" , "speedigus", "superwise", "ใช้งานแบบแห้ง", "tribofilament", "tribotape", "triflex", "twisterchain", "เมื่อมันเคลื่อนที่ igus จะพัฒนา", "xirodur", " Xiros " และ "ใช่" เป็นเครื่องหมายการค้าที่ได้รับการคุ้มครองตามกฎหมายของ igus® GmbH/ Cologne ในสหพันธ์สาธารณรัฐเยอรมนี และในกรณีที่มีผลบังคับใช้ในต่างประเทศบางประเทศ นี่เป็นรายการเครื่องหมายการค้าโดยย่อ (เช่น อยู่ระหว่างดำเนินการยื่นขอเครื่องหมายการค้าหรือเครื่องหมายการค้าจดทะเบียน) ของ igus® GmbH หรือบริษัทในเครือของ igus® ในเยอรมนี สหภาพยุโรป สหรัฐอเมริกา และ/หรือประเทศหรือเขตอำนาจศาลอื่นๆ

igus® GmbH ไม่ได้จำหน่ายผลิตภัณฑ์ใดๆ ของบริษัท Allen Bradley, B&R, Baumüller, Beckhoff, Lahr, Control Techniques, Danaher Motion, ELAU, FAGOR, FANUC, Festo, Heidenhain, Jetter, Lenze, LinMot, LTi DRiVES, Mitsubishi, NUM, Parker, Bosch Rexroth, SEW, Siemens, Stöber และผู้ผลิตไดร์ฟอื่น ๆ ทั้งหมดที่ระบุไว้ในเว็บไซต์นี้ ผลิตภัณฑ์ที่นำเสนอโดย igus® เป็นของบริษัท igus® GmbH